Add to Cart
GW3600TDS 3.6kW On Grid Solar Inverter Goodwe On Grid Inverter single phase on grid solar inverter commercial use
| DNS Series | |||||||||||
| Technical Data | GW3000D -NS | GW3600D -NS | GW4200D -NS | GW5000D -NS | GW6000D -NS | GW3000T -DS | GW3600T -DS | GW4200T -DS | GW5000T -DS | GW6000T -DS | |
| Input | |||||||||||
| Max. Input Voltage (V) | 600 | ||||||||||
| MPPT Operating Voltage Range (V) | 80 ~ 550 | ||||||||||
| Start-up Voltage (V) | 80 | ||||||||||
| Nominal Input Voltage (V) | 360 | ||||||||||
| Max. Input Current per MPPT (A) | 11 | 11 | 11 | 11 | 11 | 13 | 13 | 13 | 13 | 13 | |
| Max. Short Circuit Current per MPPT (A) | 13.8 | 13.8 | 13.8 | 13.8 | 13.8 | 16.3 | 16.3 | 16.3 | 16.3 | 16.3 | |
| Number of MPP Trackers | 2 | ||||||||||
| Number of Strings per MPPT | 1 | ||||||||||
| Output | |||||||||||
| Nominal Output Power (W)*1*2 | 3000 | 3680 | 4200 | 5000 | 6000 | 3000 | 3680 | 4200 | 5000 | 6000 | |
| Nominal Output Apparent Power (VA)*3 | 3000 | 3680 | 4200 | 5000 | 6000 | 3000 | 3680 | 4200 | 5000 | 6000 | |
| Max. AC Active Power (W)*5 | 3000 | 3680 | 4200 | 5000 | 6000 | 3000 | 3680 | 4200 | 5000 | 6000 | |
| Max. AC Apparent Power (VA)*5 | 3000 | 3680 | 4200 | 5000 | 6000 | 3000 | 3680 | 4200 | 5000 | 6000 | |
| Nominal Output Voltage (V) | 220 / 230 | ||||||||||
| Nominal AC Grid Frequency (Hz) | 50 / 60 | ||||||||||
| Max. Output Current (A) | 13.6 | 16.0 | 19.0 | 22.8 | 27.3 | 13.6 | 16.0 | 19.0 | 22.8 | 27.3 | |
| Power Factor | ~1 (Adjustable from 0.8 leading to 0.8 lagging) | ||||||||||
| Max. Total Harmonic Distortion | <3% | ||||||||||
| Efficiency | |||||||||||
| Max. Efficiency | 97.8% | ||||||||||
| European Efficiency | 97.5% | ||||||||||
| Protection | |||||||||||
| PV String Current Monitoring | - | - | - | - | - | Integrated | |||||
| PV Insulation Resistance Detection | Integrated | ||||||||||
| Residual Current Monitoring | Integrated | ||||||||||
| PV Reverse Polarity Protection | Integrated | ||||||||||
| Anti-islanding Protection | Integrated | ||||||||||
| AC Overcurrent Protection | Integrated | ||||||||||
| AC Short Circuit Protection | Integrated | ||||||||||
| AC Overvoltage Protection | Integrated | ||||||||||
| DC Switch | Optional | ||||||||||
| DC Surge Protection | Type III | Type III (Type II Optional) | |||||||||
| AC Surge Protection | Type III | ||||||||||
| AFCI | - | - | - | - | - | Optional | |||||
| Emergency Power Off | Optional | ||||||||||
| Remote Shutdown | Optional | ||||||||||
| General Data | |||||||||||
| Operating Temperature Range (ºC) | -25 ~ +60 | ||||||||||
| Relative Humidity | 0 ~ 100% | ||||||||||
| Max. Operating Altitude (m)*4 | 4000 | ||||||||||
| Cooling Method | Natural Convection | ||||||||||
| User Interface | LED, LCD, WLAN + APP | ||||||||||
| Communication | WiFi, RS485 or 4G or 2G or LAN (Optional) | ||||||||||
| Weight (kg) | 13.0 | 13.0 | 13.0 | 13.0 | 13.5 | 13.0 | 13.0 | 13.0 | 13.0 | 13.5 | |
| Dimension (W × H × D mm) | 354 × 433 × 147 | ||||||||||
| Noise Emission (dB) | <25 | <25 | <25 | <25 | <50 | <25 | <25 | <25 | <25 | <50 | |
| Topology | Non-isolated | ||||||||||
| Self-consumption at Night (W) | <1 | ||||||||||
| Ingress Protection Rating | IP65 | ||||||||||
| DC Connector | MC4 | ||||||||||
| AC Connector | Plug and play connector | ||||||||||
| *4: For Australia, Max. Operating Altitude (m) is 3000. *5: For Chile Max. AC Active Power (W) & Max. Output Apparent Power(VA): GW3000T-DS is 3000, GW3600T-DS is 3600, GW4200T-DS is 4200, GW5000T-DS is 5000, GW6000T-DS is 6000. *: Please visit GoodWe website for the latest certificates. | |||||||||||